Introduction

The P51-750-S-AF-P-20MA-000-000 is a precision sensor designed for use in industrial applications. This entry provides an overview of the product, including its category, use, characteristics, packaging, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Precision Sensor
  • Use: Industrial applications requiring accurate measurement
  • Characteristics: High precision, reliability, durability
  • Package: Compact design, suitable for integration into various systems
  • Essence: Accurate measurement of physical parameters
  • Packaging/Quantity: Typically packaged individually, quantity varies based on customer requirements

Specifications

  • Model: P51-750-S-AF-P-20MA-000-000
  • Measurement Range: 0-750 units
  • Output: 4-20mA analog signal
  • Accuracy: ±0.5% of full scale
  • Operating Temperature: -40°C to 85°C
  • Power Supply: 12-36V DC
  • Protection: IP65-rated enclosure

Detailed Pin Configuration

  1. Vcc (Power supply)
  2. GND (Ground)
  3. Signal Output

Functional Features

  • Precise measurement within the specified range
  • Linear output for easy integration with control systems
  • Robust construction for reliable operation in harsh environments
  • Easy installation and maintenance

Advantages and Disadvantages

Advantages

  • High precision measurement
  • Wide operating temperature range
  • Compatibility with standard control systems
  • Durable construction for long-term use

Disadvantages

  • Limited measurement range compared to some competing models
  • Higher initial cost compared to less precise sensors

Working Principles

The P51-750-S-AF-P-20MA-000-000 operates on the principle of converting physical parameters such as pressure or force into a proportional electrical signal. This signal is then transmitted as a 4-20mA current loop, providing a standardized output for monitoring and control systems.

Detailed Application Field Plans

Industrial Automation

  • Monitoring of hydraulic or pneumatic systems
  • Integration into manufacturing processes for quality control
  • Feedback for closed-loop control of industrial machinery

Environmental Monitoring

  • Measurement of fluid levels in tanks or reservoirs
  • Integration into weather stations for atmospheric pressure measurement

Automotive Engineering

  • Integration into vehicle suspension systems for load sensing
  • Monitoring of tire pressure in commercial vehicles

Detailed and Complete Alternative Models

  1. Model: P51-500-S-AF-P-20MA-000-000

    • Measurement Range: 0-500 units
    • Otherwise similar specifications and features
  2. Model: P51-1000-S-AF-P-20MA-000-000

    • Measurement Range: 0-1000 units
    • Otherwise similar specifications and features

In conclusion, the P51-750-S-AF-P-20MA-000-000 precision sensor offers high accuracy and reliability for a wide range of industrial applications. Its robust construction and precise measurement capabilities make it a valuable component in various systems requiring accurate monitoring and control.

[Word Count: 498]

רשום 10 שאלות ותשובות נפוצות הקשורות ליישום של P51-750-S-AF-P-20MA-000-000 בפתרונות טכניים

  1. What is the purpose of the P51-750-S-AF-P-20MA-000-000 sensor in technical solutions?

    • The P51-750-S-AF-P-20MA-000-000 sensor is used to measure pressure in various technical applications.
  2. What are the typical operating conditions for the P51-750-S-AF-P-20MA-000-000 sensor?

    • The sensor is designed to operate within a specific temperature and pressure range, typically from -40°C to 85°C and up to 750 psi.
  3. How is the P51-750-S-AF-P-20MA-000-000 sensor calibrated?

    • The sensor is factory calibrated, but it may require periodic recalibration based on the application and environmental conditions.
  4. Can the P51-750-S-AF-P-20MA-000-000 sensor be used in hazardous environments?

    • Yes, the sensor is available in intrinsically safe versions for use in hazardous locations.
  5. What output signal does the P51-750-S-AF-P-20MA-000-000 sensor provide?

    • The sensor provides a 4-20 mA output signal proportional to the measured pressure.
  6. Is the P51-750-S-AF-P-20MA-000-000 sensor suitable for use with corrosive media?

    • Depending on the specific model, the sensor can be configured with materials suitable for use with corrosive media.
  7. What is the response time of the P51-750-S-AF-P-20MA-000-000 sensor?

    • The sensor has a fast response time, typically in the milliseconds range.
  8. Can the P51-750-S-AF-P-20MA-000-000 sensor be integrated with digital control systems?

    • Yes, the sensor can be integrated with digital control systems using appropriate signal conditioning and interface modules.
  9. What is the recommended installation procedure for the P51-750-S-AF-P-20MA-000-000 sensor?

    • The sensor should be installed following the manufacturer's guidelines, including proper mounting, sealing, and electrical connections.
  10. Are there any special considerations for maintenance of the P51-750-S-AF-P-20MA-000-000 sensor?

    • Regular inspection, cleaning, and calibration checks are recommended to ensure accurate and reliable performance over time.