התמונה עשויה להיות ייצוג.
ראה מפרטים לפרטי מוצר.
P51-15-S-UCA-I36-4.5V-000-000

P51-15-S-UCA-I36-4.5V-000-000

Product Overview

Category

The P51-15-S-UCA-I36-4.5V-000-000 belongs to the category of precision pressure transducers.

Use

It is used for measuring and transmitting pressure readings in various industrial applications.

Characteristics

  • High precision
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-15-S-UCA-I36-4.5V-000-000 lies in its ability to provide accurate and reliable pressure measurements in demanding environments.

Packaging/Quantity

The product is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Model: P51-15-S-UCA-I36-4.5V-000-000
  • Pressure Range: 0-15 psi
  • Output: 4.5V
  • Electrical Connection: Integral Cable
  • Accuracy: ±0.25% FS
  • Operating Temperature: -40°C to 125°C
  • Media Compatibility: Compatible with most gases and liquids

Detailed Pin Configuration

The detailed pin configuration of the P51-15-S-UCA-I36-4.5V-000-000 includes: - Pin 1: Excitation + - Pin 2: Signal + - Pin 3: Signal - - Pin 4: Excitation -

Functional Features

  • High accuracy and repeatability
  • Built-in temperature compensation
  • Rugged design for harsh environments
  • Low power consumption
  • Fast response time

Advantages

  • Precise and reliable pressure measurements
  • Suitable for diverse industrial applications
  • Long-term stability ensures consistent performance
  • Wide operating temperature range
  • Low maintenance requirements

Disadvantages

  • May require specialized calibration equipment
  • Initial cost may be higher compared to standard pressure sensors
  • Sensitive to electromagnetic interference in certain applications

Working Principles

The P51-15-S-UCA-I36-4.5V-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into an output signal that corresponds to the applied pressure.

Detailed Application Field Plans

The P51-15-S-UCA-I36-4.5V-000-000 is suitable for a wide range of applications, including: - Industrial automation - Hydraulic systems - HVAC/R systems - Aerospace and defense - Test and measurement equipment - Process control

Detailed and Complete Alternative Models

Some alternative models to the P51-15-S-UCA-I36-4.5V-000-000 include: - P51-10-A-P-I12-4.5V-000-000 - P51-20-B-IA-I36-5V-000-000 - P51-30-C-UCA-I24-3.3V-000-000 - P51-40-D-UCA-I48-10V-000-000

In conclusion, the P51-15-S-UCA-I36-4.5V-000-000 precision pressure transducer offers high accuracy, reliability, and robustness, making it a versatile solution for various industrial pressure measurement needs.

Word Count: 497

רשום 10 שאלות ותשובות נפוצות הקשורות ליישום של P51-15-S-UCA-I36-4.5V-000-000 בפתרונות טכניים

  1. What is the application of P51-15-S-UCA-I36-4.5V-000-000?

    • The P51-15-S-UCA-I36-4.5V-000-000 is commonly used as a pressure sensor in various technical solutions.
  2. What are the key features of P51-15-S-UCA-I36-4.5V-000-000?

    • This sensor offers high accuracy, reliability, and compatibility with different systems due to its 4.5V output and compact design.
  3. How does P51-15-S-UCA-I36-4.5V-000-000 interface with other components?

    • It typically interfaces with microcontrollers or data acquisition systems through analog voltage signals.
  4. In what industries is P51-15-S-UCA-I36-4.5V-000-000 commonly used?

    • It is widely utilized in automotive, industrial automation, aerospace, and HVAC applications.
  5. What is the operating range of P51-15-S-UCA-I36-4.5V-000-000?

    • The sensor operates within a specified pressure range, usually from 0 to 15 psi.
  6. Can P51-15-S-UCA-I36-4.5V-000-000 be used in harsh environments?

    • Yes, it is designed to withstand harsh conditions and is often used in rugged industrial settings.
  7. What type of output signal does P51-15-S-UCA-I36-4.5V-000-000 provide?

    • It provides a ratiometric output of 0.5V to 4.5V, which is proportional to the applied pressure.
  8. Is calibration required for P51-15-S-UCA-I36-4.5V-000-000?

    • Yes, periodic calibration is recommended to maintain accuracy and performance.
  9. Are there any special mounting considerations for P51-15-S-UCA-I36-4.5V-000-000?

    • It should be mounted securely and in a manner that minimizes external vibrations and shocks for optimal performance.
  10. What are the typical failure modes of P51-15-S-UCA-I36-4.5V-000-000?

    • Common failure modes include electrical issues, drift in output signal, and physical damage due to excessive pressure or environmental factors. Regular maintenance and monitoring can help mitigate these risks.